[an error occurred while processing this directive] Multi-Controller.com: 8 Light Block Signals with Advance Signal on a Post (6+2)
Der Warenkorb ist leer.

Sequence Controls for Your Model Railway
Detailed Scenarios by Multi-Steuerung.de

[an error occurred while processing this directive]New Product Page

8 Light Block Signals with Advance Signal on a Post (6+2)
Controller for 8 Light Block Signals with Advance Signal on a Post in 2 groups with up to 6 and up to 2 block sections

Groups of subsequent track sections (block sections) can be secured with block signals and corresponding advance signals on the post. You control the main signals, the advance signals follow the main signals.

Order number:
ABLST_LS_0014
Available:
[an error occurred while processing this directive]
Control: analogue ✓, digital ✓, i.e. push buttons or DCC

Available as:

[an error occurred while processing this directive]
Add to basket →
L32, 8 Light Block Signals with Advance Signal on a Post (6+2)
Decoder L32 with sequence 8 Light Block Signals with Advance Signal on a Post (6+2)
  • Product Contents: L32, with sequence, configured & tested
  • Order number: L32+ABLST_LS_0014 Price: 84.00 €
[an error occurred while processing this directive][an error occurred while processing this directive]

Delivery Charges, Terms & Conditions, Imprint

[an error occurred while processing this directive]
8 Light Block Signals with Advance Signal on a Post (6+2)

Description

8 light block signals incl. advance signals on a post can be controlled. The block signals can be grouped. The advance signals can be on the post of the (previous) main signal or separate.

The advance signals follow the main block signal and switch off as soon as the own block signal shows Stop (Hp0, Red).

The Main Signals can show signal aspects Hp0 »Stop« and Hp1 »Clear«. The Advance Signals show Vr0 »Expect Stop« or Vr1 »Expect Clear«.

This sequence contains no automatic train control.

They can be activated through push buttons, toggle switches or via DCC controller.

Each group has one advance signal at entry. This is followed by a number of main signals with advance signal on a post and finally one main signal.


Block signals make sure that there is never more than one train within a block section. The block signal shows Green if the block section is clear and Red if a train is within the block section.

An advance signals can be on the post of the (previous) block signal or stand separate if at the beginning of the group. It follows the main signal automatically and shows »Expect Stop« (Yellow) or »Expect Clear« (Green).

An advance signal on a post switches off as soon as the block signal on the same post shows Stop (Red). Advance signals standing separate at the beginning of a group never switch off.

Each switching input of the decoder is connected to one block signal. As long as the contact is open, the signal shows Red. When the contact is closed, the signal shows Green. Contacts can be closed permanently with toggle switches or with push buttons for a short time. Alternatively each block signal can be switched over with 2 DCC commands.

Groups of 2 to 8 track sections in a row can be secured with block and advance signals.

The sections have a length such that each main signal (block signal) at the entry of a block section can carry the advance signal for the following block section on the same post.

This means each group contains a number of main signals with advance signal on the same post. In front of each group there is a single advance signal — for the first main signal. The last block section of each group starts with a simple main signal as no further block section follows.


Schematic Representation

[an error occurred while processing this directive]Legend: [an error occurred while processing this directive]Advance signal, Vr0 and Vr1 [an error occurred while processing this directive]Main and advance signal on a post [an error occurred while processing this directive]Main signal, Hp0 and Hp1
[an error occurred while processing this directive]Block sections can be grouped. In this example you see 2 groups of block sections with each 5 and 3 track sections

Photos

IMG_3207.JPG
IMG_3170.JPG
IMG_3254.JPG
IMG_3253.JPG
IMG_3200.JPG

Video

»Auf unserer Webseite www.multi-steuerung.de finden Sie an dieser Stelle das dazugehörige Video«
Im Video sehen Sie einen Ablauf »8 Blocksignale mit Vorsignal am Mast« in unserem Test­aufbau. [an error occurred while processing this directive]In this example you see 3 subsequent block sections, being cleared and blocked one after the other. It is nice to see how the advance signal switches off when the main signal on the same post shows »Stop«. (Distance are shortened in this layout just to demonstrate the effect.)



Setup

General Our Test Setup
scale: Z, N, TT, H0, 00…, in general any scale: H0
  • [an error occurred while processing this directive]Main signals,
  • [an error occurred while processing this directive]Main signals with advance signal on a post,
  • [an error occurred while processing this directive]Advance signals,
[an error occurred while processing this directive]in the number fitting the specific sequence
  • »H0 Signalbausatz Blocksignal mit 2 LEDs« von Conrad Electronic (211141),
  • »H0 Signalbausatz Vorsignal-Zurüstsatz mit 4 LEDs«, von Conrad Electronic (211176)
  • »H0 Signalbausatz Vorsignal mit 4 LEDs«, von Conrad Electronic (211184)

Explanation


Adaptability